Skip to content

Front and rear panels

The miniDSP Flex HT is a sophisticated device with a range of audio applications. This section of the manual explains operation of the Flex HT in its default configuration. Once you are familiar with its basic usage, read the following sections of this manual to learn how to set up more advanced configurations with miniDSP Device Console.

Once your configuration is complete, you can run Dirac Live to optimize the whole system for your room. (Dirac Live is an optional paid upgrade.)

Front panel

The front panel and rotary encoder provide access to the key features of the miniDSP Flex HT. These can also be accessed with a remote control.

miniDSP Flex HT front panel with OLED display

Volume

To change the volume, rotate the encoder. The volume changes in 0.5 dB steps. Minimum volume is -127.5 dB and maximum volume is 0.0 dB.

Preset

To select one of the four presets, press the encoder knob once, then rotate until the desired preset number is displayed. Either press the encoder knob again or wait for a second. The display will show "Pls wait..." while the new preset is being loaded, and then return to normal.

Audio source

To select an audio source, press the encoder knob twice, then rotate the encoder until the desired input source is displayed. Either press the encoder knob or wait for a second and the display will return to normal with the new input selected.

Dirac Live enable/disable

To turn Dirac Live filtering on and off, press the encoder knob three times, then rotate the encoder knob until the desired selection (on or off) is displayed. Either press the encoder knob or wait for a second and the display will return to normal with the Dirac Live status:

miniDSP Flex HT: turn Dirac Live on and off

Mute

To mute output, press and hold the encoder knob. When the display changes to show "Mute?," release the knob. To unmute, repeat this procedure.

miniDSP Flex HT: mute and unmute

Standby

To put the Flex HT into standby, press and hold the encoder knob. When the display changes to show "Standby?," release the knob. To take it out of standby, press the encoder knob.

Rear panel

Warning

Ensure all equipment is powered off when making audio connections.

Connections on the rear panel of the miniDSP Flex HT

  1. DC power. The supplied 12 VDC power supply includes a set of interchangeable power pins for USA, UK, Europe and Australia. Fit the correct pins for your country. Connect the DC plug to the 12 VDC power socket.

  2. HDMI ARC/eARC. Connect to the HDMI ARC/eARC port of a TV to receive audio.

  3. USB port. Used for both configuration/control and audio streaming. Connect to an available USB port on your computer. This port can also be connected to a network streamer with USB output for audio playback.

  4. Trigger out. Connect to trigger input on other equipment to turn it on and off. See also Trigger output timing.

  5. Optical digital input. Connect a stereo digital source using a TOSLINK optical cable. Sample rates from 32 up to 216 kHz are supported.

  6. Coax digital input. Connect a stereo digital source using an RCA cable. Sample rates from 32 up to 216 kHz are supported.

  7. Reset button. For use in specific circumstances only. See the Trouble-shooting and Support section.

  8. Analog outputs. Connect equipment such as power amplifiers and subwoofers using RCA cables. Ensure that your connections match the routing and crossovers that you have set up internally. The maximum output voltage is 2.0 Vrms.